You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 145 No. 10, October 1991 TABLE OF CONTENTS
  Archives
  •  Online Features
  THE PEDIATRIC FORUM
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Cholesterol Testing in the Physician's Office: Accuracy Assessment

NADER RIFAL, PHD; MARIET IOSEFSOHN, MS; JOCELYN M. HICKS, PHD
Department of Laboratory Medicine Children's National Medical Center The George Washington University Medical Center 111 Michigan Ave, NW Washington, DC 20010

Am J Dis Child. 1991;145(10):1087-1088.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

Sir.—To assess the quality of cholesterol testing performed outside hospital laboratories and reference clinical laboratories, we evaluated the accuracy of cholesterol measurement in 33 pediatricians' offices in the Washington, DC, metropolitan area. The participating pediatricians responded to a survey we conducted locally to determine the number of pediatricians performing cholesterol testing. Seventy-one of the 116 responding pediatricians performed cholesterol testing routinely in their practices. Sixty-five percent of those pediatricians participated in this study.

Materials and Methods.—Four frozen specimens, duplicate sets of two samples with cholesterol concentrations of 4.46 and 6.55 mmol/L, were sent to every participating pediatrician. The cholesterol concentrations of the samples were unknown to the pediatricians. The cholesterol concentrations of these sets were determined using an analyzer (Kodak Ektachem 700, Eastman Kodak Co, Rochester, NY) certified by the Centers for Disease Control—Reference Method Laboratory Network for cholesterol testing. Physicians were asked to thaw and twice analyze . . . [Full Text PDF of this Article]