You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 157 No. 3, March 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Article
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (20)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Emergency Medicine
 •Drug Therapy
 •Alert me on articles by topic

Effect of an Intervention Standardization System on Pediatric Dosing and Equipment Size Determination

A Crossover Trial Involving Simulated Resuscitation Events

Amit N. Shah, MD, MHSc; Karen Frush, MD; Xuemei Luo, PhD; Robert L. Wears, MD, MS

Arch Pediatr Adolesc Med. 2003;157:229-236.

Background  Pediatric medication dosing has been recognized as a high-error activity with the potential to cause serious harm. Few studies assess systems approaches to error reduction in pediatrics.

Objective  To estimate the decrease in deviation from recommended medication doses associated with use of a pediatric intervention standardization system in the acute setting.

Design  Two-period, 2-treatment crossover trial with data collected between December 1, 1999, and February 29, 2000.

Setting  Tertiary, academic medical center.

Participants  Convenience sample of 28 resident physicians, representing 69% of pediatrics and 50% of medicine-pediatrics residents.

Intervention  Each resident participated in 4 simulated pediatric resuscitations. The Broselow Pediatric Emergency Tape and color-coded materials were available in either the first or second 2 scenarios. Traditional dosing references were available in all scenarios.

Main Outcome Measure  Median difference between deviation from recommended dose range (DRDR) in scenarios where color coding was used (intervention) and DRDR in scenarios where color coding was not available (control).

Results  Median DRDR in intervention scenarios was 25.4% lower than in control scenarios (95% confidence interval [CI], 19.1%-32.5%; P<.001). In 4 medication prescriptions in intervention scenarios and in 54 prescriptions in control scenarios, DRDRs exceeded 100%. Median deviation from recommended equipment sizes in intervention scenarios was 0.12 size lower than in control scenarios (95% CI, 0.03-0.22 size; P<.001). Deviations in equipment size of 2 or more sizes were noted in 1 size determination in intervention scenarios and in 21 size determinations in control scenarios.

Conclusions  Color coding was associated with a significant reduction in deviation from recommended doses in simulated pediatric emergencies. Numerous potentially clinically significant deviations from recommended doses and equipment sizes were avoided. Future studies should measure impact in the real clinical setting.


From the School of Medicine (Dr Shah), Departments of Pediatrics and Surgery, Division of Emergency Medicine (Dr Frush), and Center for Clinical Effectiveness, Department of Surgery (Dr Luo), Duke University Medical Center, Durham, NC; and Department of Emergency Medicine, University of Florida Health Center, Jacksonville (Dr Wears). Dr Shah is now with the Department of Orthopaedic Surgery, Boston Medical Center, Boston, Mass.



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Medication errors: the human factor
Etchells et al.
CMAJ 2008;178:63-64.
FULL TEXT  

Patient Safety in the Pediatric Emergency Care Setting
Committee on Pediatric Emergency Medicine
Pediatrics 2007;120:1367-1375.
ABSTRACT | FULL TEXT  

Simulation and the Coming Transformation of Medical Education and Training
Becker
Radiology 2007;245:7-9.
FULL TEXT  

Enhancing Pediatric Safety: Using Simulation to Assess Radiology Resident Preparedness for Anaphylaxis from Intravenous Contrast Media
Gaca et al.
Radiology 2007;245:236-244.
ABSTRACT | FULL TEXT  

Preparation for Emergencies in the Offices of Pediatricians and Pediatric Primary Care Providers
Committee on Pediatric Emergency Medicine
Pediatrics 2007;120:200-212.
ABSTRACT | FULL TEXT  

Emergency Medical Services System Changes Reduce Pediatric Epinephrine Dosing Errors in the Prehospital Setting
Kaji et al.
Pediatrics 2006;118:1493-1500.
ABSTRACT | FULL TEXT  

Simulation of Pediatric Trauma Stabilization in 35 North Carolina Emergency Departments: Identification of Targets for Performance Improvement
Hunt et al.
Pediatrics 2006;117:641-648.
ABSTRACT | FULL TEXT  

Comparing the Utility of a Standard Pediatric Resuscitation Cart With a Pediatric Resuscitation Cart Based on the Broselow Tape: A Randomized, Controlled, Crossover Trial Involving Simulated Resuscitation Scenarios
Agarwal et al.
Pediatrics 2005;116:e326-e333.
ABSTRACT | FULL TEXT  

Prospective observational study on the incidence of medication errors during simulated resuscitation in a paediatric emergency department
Kozer et al.
BMJ 2004;329:1321.
ABSTRACT | FULL TEXT  

Evaluation of a Method to Reduce Over-the-Counter Medication Dosing Error
Frush et al.
Arch Pediatr Adolesc Med 2004;158:620-624.
ABSTRACT | FULL TEXT  

Reducing the Error in Pediatrics Dosing
Agadi
Arch Pediatr Adolesc Med 2003;157:934-934.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2003 American Medical Association. All Rights Reserved.