You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 139 No. 9, September 1985 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLES
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Transmission of Neonatal Listeriosis in a Delivery Room

Kenrad E. Nelson, MD; Dora Warren, RN, MS; Ana M. Tomasi, MD; Tonse N. Raju, MD; Dharmapuri Vidyasagar, MD

Am J Dis Child. 1985;139(9):903-905.


Abstract

• Two cases of neonatal listeriosis occurred In a hospital within a two-week period. Both infants were infected with the same organism, Listeria monocytogenes, type 1a, bacteriophage type 6 (lysotype 1652). Both infants were born in the same delivery room, 17 hours apart. The index patient became septic shortly after birth and died after 48 hours despite antibiotic therapy. The mother of the index patient was febrile and had chorioamnionitis. The second infant became ill with meningitis at 13 days of age. Neither infants nor mothers were attended by the same medical or nursing staff nor were they in the same labor or postpartum areas or nurseries. However, both infants were resuscitated in the same delivery room after birth by means of laryngoscope, suction catheter, and emergency resuscitation (Ambu) bag. Although it was hospital policy to clean and sterilize resuscitation equipment after use, the equipment had only been wiped with alcohol between patients in this instance, since sterile replacement equipment was not available during the early-morning hours when the index birth occurred. Therefore, we believe the contaminated resuscitation equipment was the source of infection in the second infant. This episode emphasizes the importance of appropriate disinfection of respiratory resuscitation equipment to prevent nosocomial infection due to L monocytogenes, an unusual but important pathogen in neonates.

(AJDC 1985;139:903-905)



Author Affiliations

From the Departments of Preventive Medicine (Dr Nelson), Internal Medicine (Dr Nelson), Obstetrics and Gynecology (Dr Tomasi), and Pediatrics (Drs Raju and Vidyasagar), and Section of Infection Control (Ms Warren), University of Illinois College of Medicine, Chicago.


Footnotes

Reprint requests to Department of Preventive Medicine, University of Illinois, 835 S Wolcott St, Chicago, IL 60612 (Dr Nelson).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1985 American Medical Association. All Rights Reserved.